The vision inspection camera takes an image of the label as the vial passes by on the manufacturing line. The camera reads the lot number and expiration date using Optical Character Recognition and reads the unique part ID by reading the barcode. All three pieces of information are passed to the Allen Bradley PLC. The expiration date and lot number must be correct for the part to pass. The PLC passes the part ID to the Microsoft Visual Studio .NET application, which checks the part ID against the database to verify that it is unique. If the part ID is found to be unique it is entered into the database to be checked against future labels.
In addition to developing the system, DMC assist the customer with risk assessments and other FDA validation needs during the initial installation and subsequent modifications to the system.
Learn more about DMC's pharmaceutical process control and medical manufacturing services.